Luminous Long Backup UPS
Luminous' world-class Home UPS and Inverter Batteries are market leaders in India—and will soon be available across the globe—thanks to years of research and development focused on customer-centric innovation. Luminous power backup solutions are used in a wide range of applications, from household appliances to commercial applications.
Features & Protection
- Micro controller based design
- Free Pre-loaded battery management software.
- SMD Technology for reliable and compact design
- Battery charging commences even at as low as 120 Volt Mains voltage
- Auto holiday mode preserves battery charge while you are away from home
- Intelligent thermal management
- Visual Indicators: Mains On, UPS On, Switch Status, Smart Charge, Overload/ Short Circuit Trip, Charger Fuse Blown, Battery Low Trip and No Load Shutdown
- Audio Alarms: Mains Fail, Fuse Fail, Battery Low Pre-alarm, Overload Trip, Battery Low Trip and No Load Shutdown
- Ensures faster battery charging
- Advanced battery management, which enhances battery life up to 70%
- Negligible battery-water loss
- Intelligent continuous charging profile adjustment
- Overload with Auto Reset
- Battery Deep Discharge Protection with Reset Option
- Ultra-Fast Short Circuit Protection
- Battery Reverse Polarity Protection
Specifications of LONG BACKUP UPS
Regulated UPS mode | ||
Under Voltage | 180 +/- 5 V | |
Undervoltage Restoration | 185 +/- 5 V | |
Over Voltage | 265 +/- 5 V | |
Over Voltage Restoration | 260 +/- 5 V | |
Unregulated UPS mode | ||
Under Voltage | 100 +/- 10 V | |
Undervoltage Restoration | 100 +/- 10 V | |
Over Voltage | 300 +/- 10 V | |
Over Voltage Restoration | 290 +/- 10Vss | |
Output | ||
Voltage (UPS Mode) | 230 V(Nominal) | |
Voltage (Mains Mode) | Same as Input | |
Frequency (UPS Mode) | 50Hz.±2% | |
Frequency (Mains Mode) | Same as Input (45-55 Hz.) | |
Overload | > 110 ‰ | |
Transfer Time (typical a.s) | 10ms. | |
Battery | Type | 12V/120AH-150AH Lead Acid Type |
Number | 1 | |
Typical Recharge Time | 10-12 Hrs. | |
Protection | Battery Deep Discharge, Reverse Polarity, DC Overvoltage | |
LED DISPLAY | ||
UPS ON | Red | |
SWITCH ON | White | |
Low Battery Pre-Alarm | UPS ON+LOW BATTERY LED BLINKS | |
Battery Low | Red | |
Mains On | Red | |
Smart Charge | Red (Along with Mains On LED) | |
Overload | Red | |
Short Circuit | OVERLOAD BLINKING | |
No Load Shut Down | Red | |
Battery Charged | Mains On LED steady | |
Charging Fuse Blown | Mains On (Continuos) with Smart Charge LED (blinking) | |
ALARMS | Low Battery Pre-Alarm | Beeps every 10 seconds |
Low Battery Trip | Beeps Continuously for 10 seconds | |
Overload | Beeps Continuously for 10 seconds | |
Mains to UPS | Beeps every 2 seconds for 5 times | |
Short Circuit | Beeps Continuously for 10 seconds | |
No Load Shut Down | Beeps Continuously for 10 seconds | |
Charging Fuse Blown | Beeps Continuously for 10 seconds | |
ENVIRONMENTAL | ||
Operating Temperature | 0-45o C (32-113 o F) | |
Storage Temperature | 0-45o C (32-113 o F) | |
Humidity | 0-95 % RH non -condensing |